This newly created room was once the center of the garage area for the originally building – a fire station. Because of this, the floor was highly sloped downward toward a center drain. The floor was filled to the best of their contractor’s ability, but still left a 1″+ variance across the 16 foot opening. The Hufcor operable panel partition allowed for correction of this problem with the use of their standard operable bottom seal. This retractable seal allows the owner to move the panels easily across the opening before locking them in place by expanding the bottom seals.